Description
111148.00 – Leeson 1.50 HP Condenser Fans HVAC/R Motor, 3 phase, 1200 RPM, 208-230/460 V, 56Y Frame, DPAO – 111148.00
111148.00 Leeson Condenser Fans Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: |
691720009635 |
Weight: |
45 LB |
Packaged Length: |
19.5 IN |
Packaged Width: |
10.44 IN |
Packaged Height: |
10.88 IN |
Nameplate Specifications
Output HP: |
1.50 Hp |
Output KW: |
1.1 kW |
Frequency: |
60 Hz |
Voltage: |
208-230/460 V |
Current: |
5.7-5.6/2.8 A |
Speed: |
1140 rpm |
Service Factor: |
1.15 |
Phase: |
3 |
Efficiency: |
79 % |
Power Factor: |
68 |
Duty: |
Continuous |
Insulation Class: |
B |
Design Code: |
B |
KVA Code: |
J |
Frame: |
56Y |
Enclosure: |
Drip Proof Air Over |
Thermal Protection: |
Automatic |
Ambient Temperature: |
40 °C |
Drive End Bearing Size: |
6203 |
Opp Drive End Bearing Size: |
6203 |
UL: |
Recognized |
CSA: |
Y |
CE: |
N |
IP Code: |
22 |
Technical Specifications
Electrical Type: |
Squirrel Cage Induction Run |
Starting Method: |
Across The Line |
Poles: |
6 |
Rotation: |
Reversible |
Resistance Main: |
0 Ohms |
Mounting: |
Round Belly Band |
Motor Orientation: |
Shaft Up |
Drive End Bearing: |
Ball |
Opp Drive End Bearing: |
Ball |
Frame Material: |
Rolled Steel |
Shaft Type: |
Single Special Extension |
Overall Length: |
15.06 in |
Frame Length: |
7.50 in |
Shaft Diameter: |
0.625 in |
Shaft Extension: |
3.75 in |
Assembly/Box Mounting: |
F1/F2 CAPABLE |
Speed Characteristics
Curvepoint |
Current (Amps) |
Current (%) |
Torque (ft-lbs) |
(%) |
Speed (RPM) |
Rated Output (KW) |
Power Factor (%) |
Rated Output (Hp) |
Break-Down |
10.10 |
180.0 |
21.00 |
309.0 |
800 |
6.00 |
0.0 |
1.50 |
Pull-Up |
14.90 |
266.0 |
16.50 |
243.0 |
120 |
7.41 |
0.0 |
1.50 |
Locked-Rotor |
30.00 |
535.0 |
16.50 |
243.0 |
0 |
7.46 |
0.0 |
1.50 |
Full Load |
5.60 |
100.0 |
6.80 |
100.0 |
1,159 |
1.39 |
68.0 |
1.50 |
Load Characteristics
% of Rated Load |
0 % |
25 % |
50 % |
75 % |
100 % |
125 % |
150 % |
Current (Amps) |
2.07 |
2.15 |
2.35 |
2.58 |
2.80 |
3.27 |
3.70 |
Rated Output (KW) |
0.15 |
0.45 |
0.75 |
1.39 |
1.39 |
1.72 |
2.07 |
Efficiency (%) |
0.0 |
64.6 |
76.0 |
61.2 |
80.5 |
79.5 |
77.6 |
Power Factor (%) |
8.8 |
26.0 |
40.1 |
67.4 |
62.3 |
66.1 |
70.1 |
Speed (RPM) |
1,199 |
1,190 |
1,180 |
1,170 |
1,159 |
1,146 |
1,117 |
Temp. Rise @ FL |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Torque (ft-lbs) |
0.00 |
1.70 |
3.40 |
5.10 |
6.80 |
8.40 |
10.10 |
Leeson Motors