Description
182TCFW9061 – Marathon 2 HP General Purpose Farm Duty Motor, 1 phase, 1800 RPM, 115/230 V, 182TZ Frame, TEFC – Z112A
182TCFW9061 Marathon Single Phase Farm Duty Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: |
722856261120 |
Weight: |
68 LB |
Packaged Length: |
20.13 IN |
Packaged Width: |
14.63 IN |
Packaged Height: |
12.38 IN |
Nameplate Specifications
Output HP: |
2 Hp |
Output KW: |
1.5 kW |
Frequency: |
60 Hz |
Voltage: |
115/230 V |
Current: |
24.0/12.0 A |
Speed: |
1760 rpm |
Service Factor: |
1.15 |
Phase: |
1 |
Efficiency: |
74 % |
Power Factor: |
72.5 |
Duty: |
Continuous |
Insulation Class: |
F |
Design Code: |
N |
KVA Code: |
L |
Frame: |
182TZ |
Enclosure: |
Totally Enclosed Fan Cooled |
Thermal Protection: |
Manual |
Ambient Temperature: |
40 °C |
Drive End Bearing Size: |
6206 |
Opp Drive End Bearing Size: |
6205 |
UL: |
Recognized ( Not Protector) |
CSA: |
Y |
CE: |
Y |
IP Code: |
43 |
Technical Specifications
Electrical Type: |
Capacitor Start Induction Run |
Starting Method: |
Across The Line |
Poles: |
4 |
Rotation: |
Selective Counterclockwise |
Resistance Main: |
0 Ohms |
Mounting: |
Rigid Base |
Motor Orientation: |
Horizontal |
Drive End Bearing: |
Ball |
Opp Drive End Bearing: |
Ball |
Frame Material: |
Rolled Steel |
Shaft Type: |
Single Special Extension |
Overall Length: |
14.46 in |
Frame Length: |
9.00 in |
Shaft Diameter: |
0.875 in |
Shaft Extension: |
2.81 in |
Assembly/Box Mounting: |
F1 ONLY |
Speed Characteristics
Curvepoint |
Current (Amps) |
Current (%) |
Torque (ft-lbs) |
(%) |
Speed (RPM) |
Rated Output (KW) |
Power Factor (%) |
Rated Output (Hp) |
Break-Down |
41.00 |
342.0 |
16.70 |
280.0 |
1,560 |
0.00 |
0.0 |
2.00 |
Locked-Rotor |
80.00 |
667.0 |
19.50 |
327.0 |
0 |
0.00 |
0.0 |
2.00 |
Pull-Up |
50.00 |
417.0 |
16.80 |
282.0 |
1,480 |
0.00 |
0.0 |
2.00 |
Full Load |
12.00 |
100.0 |
5.96 |
100.0 |
1,760 |
0.00 |
0.0 |
2.00 |
Load Characteristics
% of Rated Load |
0 % |
25 % |
50 % |
75 % |
100 % |
115 % |
125 % |
150 % |
Current (Amps) |
7.55 |
8.00 |
8.90 |
10.20 |
12.00 |
13.20 |
14.00 |
16.30 |
Rated Output (KW) |
0.33 |
0.70 |
1.10 |
1,535.00 |
2.00 |
2.30 |
2.50 |
3.05 |
Efficiency (%) |
0.0 |
53.6 |
67.7 |
70.0 |
74.0 |
74.3 |
74.2 |
73.1 |
Power Factor (%) |
19.0 |
38.0 |
53.7 |
65.0 |
72.5 |
75.8 |
77.6 |
81.4 |
Speed (RPM) |
1,800 |
1,785 |
1,776 |
1,764 |
1,760 |
1,752 |
1,744 |
1,730 |
Temp. Rise @ FL |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Torque (ft-lbs) |
0.00 |
1.48 |
2.95 |
4.44 |
5.96 |
6.87 |
7.49 |
9.07 |
Marathon Motors
Regal Beloit