213TTGN6576 – Marathon 3 HP Explosion Proof Motor, 3 phase, 1200 RPM, 230/460 V, 213T Frame, EPFC – U042A
213TTGN6576 Marathon Explosion Proof NEMA Motors
Please advise CFM, static pressure, voltage, phase, and/or horsepower on specifications, drawings, or existing equipment for an accurate quote.
General Specifications
UPC: |
722856023285 |
Weight: |
216 LB |
Packaged Length: |
27 IN |
Packaged Width: |
20.5 IN |
Packaged Height: |
18 IN |
Nameplate Specifications
Output HP: |
3 Hp |
Output KW: |
2.2 kW |
Frequency: |
60 Hz |
Voltage: |
230/460 V |
Current: |
8.8/4.4 A |
Speed: |
1170 rpm |
Service Factor: |
1.15 |
Phase: |
3 |
Efficiency: |
89.5 % |
Power Factor: |
70 |
Duty: |
Continuous |
Insulation Class: |
F |
Design Code: |
B |
KVA Code: |
K |
Frame: |
213T |
Enclosure: |
Explosion Proof Fan cooled |
Thermal Protection: |
Thermostats (N/C) |
Ambient Temperature: |
40 °C |
Drive End Bearing Size: |
6307 |
Opp Drive End Bearing Size: |
6208 |
UL: |
UL Listed; also, UL Certified for Canada |
CSA: |
N |
CE: |
N |
IP Code: |
54 |
Hazardous Location: |
EXP PROOF CL I GR D CL II GR F&G T3B |
Technical Specifications
Electrical Type: |
Squirrel Cage Inverter Rated |
Starting Method: |
Line Or Inverter |
Poles: |
6 |
Rotation: |
Reversible |
Resistance Main: |
2.785 Ohms |
Mounting: |
Rigid base |
Motor Orientation: |
Horizontal |
Drive End Bearing: |
Ball |
Opp Drive End Bearing: |
Ball |
Frame Material: |
Cast Iron |
Shaft Type: |
T |
Overall Length: |
19.63 in |
Frame Length: |
9.12 in |
Shaft Diameter: |
1.375 in |
Shaft Extension: |
3.48 in |
Assembly/Box Mounting: |
F1 ONLY |
Speed Characteristics
Curvepoint |
Current (Amps) |
Current (%) |
Torque (ft-lbs) |
(%) |
Speed (RPM) |
Rated Output (KW) |
Power Factor (%) |
Rated Output (Hp) |
Pull-Up |
28.00 |
636.0 |
32.00 |
237.0 |
600 |
|
|
3.00 |
2/3 |
25.00 |
568.0 |
37.00 |
274.0 |
800 |
|
|
3.00 |
No Load |
2.70 |
61.0 |
0.00 |
0.0 |
1,200 |
|
|
3.00 |
1/3 |
30.00 |
682.0 |
31.00 |
230.0 |
400 |
|
|
3.00 |
Locked-Rotor |
32.00 |
727.0 |
34.00 |
252.0 |
0 |
|
40.0 |
3.00 |
Break-Down |
20.00 |
455.0 |
47.50 |
352.0 |
1,025 |
|
65.0 |
3.00 |
Full Load |
4.40 |
100.0 |
13.50 |
100.0 |
1,170 |
|
|
3.00 |
Load Characteristics
% of Rated Load |
0 % |
25 % |
50 % |
75 % |
100 % |
115 % |
125 % |
133 % |
Current (Amps) |
2.50 |
2.70 |
3.20 |
3.80 |
4.40 |
5.00 |
5.30 |
5.50 |
Rated Output (KW) |
0.20 |
0.70 |
1.30 |
1.90 |
2.50 |
3.00 |
3.20 |
3.38 |
Efficiency (%) |
0.0 |
81.0 |
87.5 |
89.5 |
89.5 |
89.5 |
88.5 |
88.5 |
Power Factor (%) |
6.0 |
32.0 |
49.5 |
62.0 |
70.0 |
73.0 |
75.0 |
77.5 |
Speed (RPM) |
1,200 |
1,194 |
1,186 |
1,180 |
1,170 |
1,168 |
1,166 |
1,163 |
Temp. Rise @ FL |
0.0 |
30.0 |
25.0 |
0.0 |
35.0 |
45.0 |
55.0 |
65.0 |
Torque (ft-lbs) |
0.00 |
3.30 |
6.70 |
10.00 |
13.50 |
15.50 |
17.00 |
19.00 |
Marathon Motors